Cisco ONS 15454 SDH Specifications Page 164

  • Download
  • Add to my manuals
  • Print
  • Page
    / 504
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 163
3-24
Cisco ONS 15454 SDH Installation and Operations Guide, R3.3
May 2002
Chapter 3 Node Setup
Creating Card Protection Groups
BITS 1 Out/BITS 2 OutSet to None
Step 6 Click Apply.
Step 7 Log into a node that will be timed from the node set up in Step 1 to Step 6.
Step 8 In the CTC node view, click the Provisioning > Timing tabs.
Step 9 In the General Timing section, enter the following:
Timing ModeSet to Line.
RevertiveNot relevant for internal timing; the default setting (checked) is sufficient.
Revertive TimeThe default setting (5 minutes) is sufficient.
Step 10 In the Reference Lists section, enter the following:
NE Reference
Ref-1Use the pull-down menu to choose the STM-N trunk card with the closest connection
to the node in Step 3.
Ref-2Use the pull-down menu to choose the STM-N trunk card with the next closest
connection to the node in Step 3.
Ref-3Use the pull-down menu to choose Internal Clock.
Step 11 Click Apply.
Step 12 Repeat Step 7 to Step 11 at each node that will be timed by the node serving as the timing source.
3.6 Creating Card Protection Groups
The ONS 15454 SDH provides several card protection methods. When you set up protection for ONS
15454 SDH cards, you must choose between maximum protection and maximum slot availability. The
highest protection reduces the number of available card slots; the highest slot availability reduces the
protection. Table 3-6 shows the protection types that can be set up for ONS 15454 SDH cards.
Table 3-6 Protection Types
Type Cards Description
1:1 E1-N-14
E3-12
DS3i-N-12
Pairs one working card with one protect card. Install the protect card in
an odd-numbered slot and the working card in an even-numbered slot
next to the protect slot towards the center, for example: protect in Slot
1, working in Slot 2; protect in Slot 3, working in Slot 4; protect in Slot
15, working in Slot 14.
1:N E1-N-14
DS3i-N-12
Assigns one protect card for several working cards. The maximum is
1:5. Protect cards (E1-N-14, DS3i-N-12) must be installed in Slots 3 or
15 and the cards they protect must be on the same side of the shelf.
Protect cards must match the cards they protect. For example, a
E1-N-14 can only protect E1-N-14 cards. If a failure clears, traffic
reverts to the working card after the reversion time has elapsed.
Page view 163
1 2 ... 159 160 161 162 163 164 165 166 167 168 169 ... 503 504

Comments to this Manuals