7-11
Cisco ONS 15454 SDH Installation and Operations Guide, R3.3
May 2002
Chapter 7 Card Provisioning
Provisioning Electrical Cards
ES Errored seconds Numeric. Default:
20 (15 minutes)
200 (1 day)
SES Severely errored seconds Numeric. Default:
3 (15 minutes)
7 (1 day)
UAS Unavailable Seconds Numeric. Default:
10 (15 minutes)
10 (1 day)
SDH Thresholds (SDH Thrshld subtab)
Port # Port number 1 - 12
ES Errored seconds Numeric. Default (VC LO):
12 (15 minutes)
100 (1 day)
SES Severely errored seconds Numeric. Default (VC LO)
3 (15 minutes)
7 (1 day)
EB Errored blocks Numeric. Default (VC LO):
15 (15 minutes)
125 (1 day)
UAS Unavailable seconds Numeric. Default (VC LO):
10 (15 minutes)
10 (1 day)
BBE Background block error Numeric. Default (VC LO):
15 (15 minutes)
125 (1 day)
ES Errored seconds Numeric. Default (VC HO):
20 (15 minutes)
200 (1 day)
SES Severely errored seconds Numeric. Default (VC HO)
3 (15 minutes)
7 (1 day)
EB Errored blocks Numeric. Default (VC HO):
15 (15 minutes)
125 (1 day)
Table 7-4 E3-12 Card Parameters (continued)
Parameter Description Options
Comments to this Manuals