7-5
Cisco ONS 15454 SDH Installation and Operations Guide, R3.3
May 2002
Chapter 7 Card Provisioning
Provisioning Electrical Cards
• E1-N-14
• E3-12
• DS3i-N-12
When you open a card in CTC (which means double-click on this card) and choose the Provisioning tab,
the following subtabs are commonly displayed:
• Line—Sets line setup parameters, such as line type, line coding, and line length. This is also where
you put ports in and out of service.
• Line Thrshld—Sets the line-level PM thresholds.
• Elect Path Thrshld—Sets the path-level PM thresholds for electrical (E1, E3, DS3) traffic.
• SDH Thrshld—Sets the path-level PM thresholds for SDH traffic.
• Alarming—Sets alarm profiles for individual ports. See Chapter 10, “Alarm Monitoring and
Management.” for information about creating alarm profiles.
As an example, Figure 7-4 shows the screen with the choices for an E1-N-14 card.
Figure 7-4 Provisioning line parameters on the E1-N-14 card
Table 7-2 provides an overview of E1-N-14, E3-12, and DS3i-N-12 parameters (an X means the item is
available for the card).