9-45
Cisco ONS 15454 SDH Installation and Operations Guide, R3.3
May 2002
Chapter 9 Ethernet Operation
G1000-4 Performance and Maintenance Screens
Figure 9-36 G1000-4 Statistics window
Note The CTC automatically refreshes the counter values once right after a Baseline operation, so if traffic is
flowing during a baseline operation, some traffic counts may immediately be observed instead of zero
counts.
Note The Clear button will not cause the G1000-4 card to reset. Provisioning, enabling, or disabling a
G1000-4 port will not reset the statistics.
Table 9-9 G1000-4 Statistics Values
Baseline Clicking Baseline resets the software counters (in that particular CTC client only)
temporarily to zero without affecting the actual statistics on the card. From that point
on, only the change (delta) in counters are displayed by this CTC. These new base
lined counters display only as long as the user displays the Performance pane. If the
user navigates to another pane and comes back to the Performance pane, the true
actual statistics retained by the card display.
Refresh Manually refreshes the statistics
Auto-Refresh Sets a time interval for the automatic refresh of statistics
Clear Resets the actual counters on the card to zero; this change is recognized by all
management clients.
Refresh
67888
Statistics
Utilization
Performance
Auto-refresh
History
Baseline
Clear