xconnect
xconnect
To bind an attachment circuit to a pseudowire, use the xconnect command in one of the supported
configuration modes. To restore the default values, use the no form of this command.
xconnect peer-ip-address | vcid | pseudowire-parameters
no xconnect
Syntax Description
Defaults The attachment circuit is not bound to the PW.
Command Modes CEM circuit configuration
Interface configuration
Subinterface configuration
l2transport configuration (for ATM)
Connect configuration
Global configuration
Command History
peer-ip-address IP address of the remote provider edge (PE) peer. The remote router ID can
be any IP address, as long as it is reachable.
vcid The 32-bit identifier of the virtual circuit (VC) between the PE routers.
pseudowire-parameters Encapsulation and pseudowire-class parameters to be used for the
attachment circuit. At least one of the following PW parameters must be
configured:
encapsulation {l2tpv3 | mpls}— Specifies the tunneling method to
encapsulate the data in the PW:
l2tpv3—Specifies L2TPv3 as the tunneling method.
mpls—Specifies MPLS as the tunneling method.
Note L2TP is not currently supported on the Cisco MWR 2941.
pw-class pw-class-name—Specifies the pseudowire-class
configuration from which the data encapsulation type is taken. This
option is mandatory if you select an encapsulation method.
transmit Sequences data packets received from the attachment circuit.
receive Sequences data packets sent into the attachment circuit.
both Sequences data packets that are both sent and received from the attachment
circuit.
Release Modification
12.0(23)S This command was introduced.
12.0(28)S Support was added for Multilink Frame Relay connections.
Page view 706