Cisco SCE 1000 2xGBE User's Guide Page 104

  • Download
  • Add to my manuals
  • Print
  • Page
    / 490
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 103
Chapter 4 Installation and Startup
System Configuration
SCE 1000 2xGBE Release 2.0.10 User Guide
4-42 OL-7117-02
The procedure described below is a hypothetical presentation of all the questions in the topology
configuration. In actual practice, it is impossible for all questions to be presented in any one
configuration, as this part of the dialog is not linear like the other sections, but branches
depending on the parameter values entered.
Study the examples that follow to understand the procedure for various topologies.
To configure topology dependent parameters:
Step 1 Enter the topology configuration menu.
Would you like to enter the Topology configuration menu? [no]: y
Type y and press Enter.
The topology configuration dialog begins.
Step 2 Specify the connection mode.
To define inline connection mode, press Enter.
To define receive-only connection mode, type 2 and press Enter.
Enter Connection mode:
1- inline
2- receive-only
Enter your choice [1]:
Step 3 Specify the On-failure link behavior.
To specify Bypass, press Enter.
To specify Cutoff, type 2 and press Enter.
Enter On-failure behavior:
1- bypass
2- cutoff
Enter your choice [1]:
Step 4 Specify the admin status of the SCE 1000 after abnormal boot.
To specify Not-Operational status after abnormal boot, press Enter.
To specify Operational status after abnormal boot, type 1 and press Enter.
Enter admin status of the SCe after abnormal boot:
1- Operational
2- Not-Operational
Enter your choice [1]:
The following examples present the procedure for configuring the topology-related parameters for
various topologies. Refer the Topology Configuration Summary Table (on page 2-10) for a
summary of appropriate values for the parameters for each topology.
EXAMPLE #1:
Following is a sample topology configuration for a topology using an external switch.
All other parameter values are automatically assigned by the system as follows:
Link bypass mode on-failure: Bypass
Admin status of the SCE after abnormal boot: Operational
Page view 103
1 ... 103 104 105 ... 490

Comments to this Manuals

No comments