Cisco SCE 1000 2xGBE User's Guide Page 159

  • Download
  • Add to my manuals
  • Print
  • Page
    / 490
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 158
Chapter 6 Control Configuration
SNTP
SCE 1000 2xGBE Release 2.0.10 User Guide
OL-7117-02 6-13
Setting the Time Zone
To set the current time zone:
Step 1 From the SCE 1000(config)# prompt, type clock timezone <zone>
<hours>, where <zone> is the name of the time zone and <hours> is the offset from
GMT.
EXAMPLE:
The following example shows how to set the time zone to Pacific Standard Time with an offset of
10 hours behind GMT.
SCE 1000(config)#clock timezone PST –10
SCE 1000(config)#
Note
You can configure time zones that do not differ from GMT by a multiple of one hour. Consult the CLI
Command Reference (on page A-1) regarding the clock timezone global configuration command.
Removing Current Time Zone Setting
To remove the current time zone setting:
Step 1 From the SCE 1000(config)# prompt, type no clock timezone and press
Enter.
The default time zone is UTC (GMT).
EXAMPLE:
The following example shows how to remove the time zone setting.
SCE 1000(config)#no clock timezone
SNTP
The Simple Network Timing Protocol (SNTP) is a simple solution to the problem of
synchronizing the clocks in the various elements of the network. SNTP provides access to a time
source via the network. The system clock and calendar are then set in accordance with this
external source.
There are two options for the SNTP client. These functions are independent, and the system
employ either one or both.
Multicast SNTP client: Listens to SNTP broadcasts and updates the system clock accordingly.
Page view 158
1 ... 158 159 160 ... 490

Comments to this Manuals