System Group: systemGrp (pcubeSEObjs 1)
SCE 1000 2xGBE Release 2.0.10 User Guide
OL-7117-02 B-17
chassisLineFeedAlarmOnTrap (pcubeSeEvents 36)
The agent entity has detected that the chassisLineFeed object in this MIB has changed to the
on(3) state.
System Group: systemGrp (pcubeSEObjs 1)
The System group provides data on the system-wide functionality of the SCE Platform.
sysOperationalStatus (systemGrp 1)
Indicates the operational status of the system.
Access RO
S
YNTAX
INTEGER {
1 (other): none of the following
2 (boot): the system is in boot process
3 (operational): the system is operational
4 (warning): the system is in Warning status
5 (failure): the system is in Failure status
}
sysFailureRecovery (systemGrp 2)
Indicates the behavior of the system after abnormal boot.
Access RO
S
YNTAX
INTEGER {
1 (other): none of the following
2 (operational): the system should enter Operational mode after abnormal boot
3 (non-operational): the system should enter Failure mode after abnormal boot
}
sysVersion (systemGrp 3)
The system version.
Access RO
S
YNTAX
DisplayString