Cisco SCE 1000 2xGBE User's Guide Page 254

  • Download
  • Add to my manuals
  • Print
  • Page
    / 490
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 253
Chapter 10 Troubleshooting
RDR Reports
SCE 1000 2xGBE Release 2.0.10 User Guide
10-6 OL-7117-02
Symptom How to look for the
specific cause
Possible Cause Resolution
CLI Commands:
show telnet sessions
Too many Telnet connections
(up to 5 concurrent sessions are
supported)
Close one or more of
the open Telnet
sessions
CLI Commands:
show ip default-gateway
Default gateway is incorrect
(when the host used as client is
not in the same network as the
SCE Platform)
Check / reconfigure
default gateway.
Refer to Default
Gateway. ("Default
Gateway" on page 6-8)
CLI commands:
show ip route <host-ip-
address>
Routing tables are incorrectly
configured (when the host used
as client is not in the same
network as the SCE Platform,
and there is more than one
gateway on the SCE Platform
network)
Check / reconfigure
routing tables.
Refer to IP Routing
Table (on page 6-7).
CLI commands:
show access-lists
show line vty access-class
show ip access-class
Host is not a member of a valid
access-list
Check / reconfigure
access-list.
Refer to Configuring
Access Control Lists
(ACLs) (on page 6-2).
Telnet
connection
terminates
automatically
CLI commands:
show line vty timeout
There is a timeout configured
on Telnet sessions
Check / reconfigure
line timeout (use no
timeout to disable
timeout).
Refer to Telnet
Timeout.
RDR Reports
The main cause for missing RDR reports can be a management link problem. For the
troubleshooting of management link problems, see section Management Link (on page 10-5) in
this chapter.
The following table describes the different cases that might lead to a RDR reporting problem,