Chapter 6 Control Configuration
The RDR Formatter
SCE 1000 2xGBE Release 2.0.10 User Guide
6-26 OL-7117-02
Configuring the destinations with the proper priorities for each category, as well as configuring all
the other RDR formatter parameters, may be approached in several different ways, and may take
some planning. Refer to the examples below for illustrations of some of the issues involved in
configuring categories.
To configure an RDR Formatter category name:
Step 1 From the SCE 1000(config)# prompt, type RDR-Formatter category-
number 1|2 name <category-name>, and press Enter.
The name for the specified category number is defined. This category name can then be
used in any RDR-formatter command instead of the category number.
To configure a RDR Formatter destination and assign it to a category:
Step 1 From the SCE 1000(config)# prompt, type RDR-Formatter destination
<IP address> port <port-number> category [name <category-
name> |number [1|2]] [priority <priority(1-100)>] [category
[name <category-name> |number [1|2]] [priority <priority(1-
100)>]], and press Enter.
The RDR Formatter destination is defined. A different priority may be assigned to each
category. (This can be done in one command.) If RDRs from the specified category
should be sent to this destination, the priority for the category should be high. If the
RDRs from the specified category should not be sent to this destination, the priority
should be low.
Note that within each category the priorities must be unique for each destination.
Comments to this Manuals