Cisco SCE 1000 2xGBE User's Guide Page 113

  • Download
  • Add to my manuals
  • Print
  • Page
    / 490
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 112
Chapter 4 Installation and Startup
Connecting the line ports to the network
SCE 1000 2xGBE Release 2.0.10 User Guide
OL-7117-02 4-51
The SCE 1000(config if)# prompt appears.
Step 3 Type auto-negotiate and press Enter.
The SCE 1000(config if)# prompt appears.
Step 4 To return to Global Configuration Mode, type exit and press Enter.
The SCE 1000(config)# prompt appears.
Follow the next procedure to configure auto-negotiation for the second GBE port
interface
To configure speed and duplex for the second GBE port (network side) interface:
Step 1 At the SCE 1000(config)# prompt, to enter the second GBE port interface, type
interface GigabitEthernet 0/2, and press Enter.
The SCE 1000(config if)# prompt appears.
Step 2 Type auto-negotiate and press Enter.
The SCE 1000(config if)# prompt appears.
Step 3 To return to Global Configuration Mode, type exit and press Enter.
The SCE 1000(config)# prompt appears.
Step 4 To exit Global Configuration Mode, type exit and press Enter.
The SCE 1000# prompt appears.
Note
Auto-negotiation must be disabled when the SCE 1000 is deployed via an external optical splitter (i.e.
passive topology).
Connecting Subscriber Side and Network Side Ports
Note that the SCE 1000 ports are not symmetric. The left-hand port is the Subscriber side port,
and the right-hand port is the Network side port, as labeled on the front panel.
Page view 112
1 ... 112 113 114 ... 490

Comments to this Manuals

No comments