Chapter 10 Troubleshooting
RDR Reports
SCE 1000 2xGBE Release 2.0.10 User Guide
10-8 OL-7117-02
Symptom How to look for the
specific cause
Possible Cause Resolution
No RDR
reports
• System operation-status
problem
System status is not
Operational Front
panel LEDs indications.
CLI commands:
show system
operation-status
• Boot time failure
• Run time failure
• Link problems
Check the system status,
front panel LEDs and user
log file for problem
indications. Handle the
problem according to the
warning / error in the user
log.
Refer to Verifying
Operational Status (on
page 4-55).
RDR reports
are not
generated due
to traffic
problems
If all previous options were
correctly functioning /
configured, check if traffic
reaches the SCE Platform.
CLI commands:
show interface
GigabitEthernet 0/#
counters
Check printout of this
command for: “In good
unicast packet”. This
counter should be constantly
incrementing in both ports.
Traffic connection may be
cutoff at the SCE Platform or
its peers
Check GBE interface link
LEDs.
Check auto-negotiation
configuration in the SCE
Platform and its peers.
show interface
GigabitEthernet 0/#
GigabitEthernet interfaces
auto-negotiation may be
incorrectly configured.
• Check / reconnect the
cable to the GBE port
• Check / replace the
cable