Appendix A
Global Configuration Mode Commands
SCE 1000 2xGBE Release 2.0.10 User Guide
A-12 OL-7117-02
no enable password [level level]
Resets the password for the specified authorization level to the default value. For the user level,
this means that no password is required. For the admin and root levels, the password is restored to
the default value ‘pcube’.
Authorization admin
Mode Global Configuration
Default pcube
P
ARAMETERS
level User authorization level (0, 10, 15) as specified in in Login and User Levels
(on page A-3), in table Authorization Levels. If no level is specified,
the default is Admin (10).
E
XAMPLE:
The following example removes the requirement for user level password.
SCE 1000(config)#no enable password level 0
SCE 1000(config)#
[no | default] failure-recovery operation-mode mode
Specifies the operation mode to be applied after boot resulting from failure. When using the [no]
or [default] switch, you do not have to specify the mode.
Default operational
Authorization admin
Mode Global Configuration
P
ARAMETERS
mode operational or non-operational. Indicates whether the system will
boot as operational or not following a failure.
E
XAMPLE:
The following example sets the system to boot as operational after a failure
SCE 1000(config)#failure-recovery operation-mode operational
SCE 1000(config)#
Comments to this Manuals