RDR Reports
SCE 1000 2xGBE Release 2.0.10 User Guide
OL-7117-02 10-7
Table 10-3 RDR Reports
Symptom How to look for the
specific cause
Possible Cause Resolution
No RDR
reports
Configuration problems
No RDR
reports are
sent from the
SCE Platform
CLI commands:
show RDR-
formatter
connection-status
(Connection is down)
show RDR-
formatter
counters
RDR connection is not
configured or configured to
a host which is non-
functional
Check / configure RDR
destination.
Refer to The RDR
Formatter (on page 6-
19).
RDR formatter
fails to
connect to the
Collection
Manager
CLI commands:
show ip access-
class
The Collection Manager is
denied by IP access list.
Management Link
problems.
Check IP ACL
configuration
Refer to Defining the
Global Access List (on
page 6-4).
Refer to Management
Link (on page 10-5).
RDR
connection is
setup correctly
but reports are
not generated
CLI commands:
show RDR-formatter
counters
Counters show that RDR did
not read any events.
No application is
configured to Linecard
CLI command
show interface
LineCard 0
Refer to the to the
relevant application user
guide.
CLI commands:
show interface
linecard #
Linecard is in shutdown
mode
Change Linecard mode
to no shutdown.
Refer to LineCard
Interface Configuration
Mode.
Linecard is in silent mode Change Linecard mode
to no silent.
Refer to LineCard
Interface Configuration
Mode.