Chapter 10 Troubleshooting
GBE Interfaces Connectivity
SCE 1000 2xGBE Release 2.0.10 User Guide
10-10 OL-7117-02
GBE Interfaces Connectivity
In general, the case where no traffic is coming out of the SCE 1000 is often caused by link
problems or GBE interface configuration. Note that in some cases, the problem which seems as a
transmit problem could be in the Rx (no traffic is being received by the SCE 1000 or there is
actually no traffic on the line, which could be a normal situation).
In CLI commands of GigabitEthernet interfaces, # stands for the number of the interface. This can
be 1 or 2.
Table 10-4 Network Interfaces Connectivity
Symptom How to look for the
specific cause
Possible Cause Resolution
Interface connectivity problem
GE interface
link LED is off
CLI commands:
• show interface
GigaBitEthernet
0/# counters
Check printout of this
command for: “In good
unicast packet” and “Out
unicast packet”. These
counters should be
constantly incrementing.
• show interface
GigaBitEthernet
0/#
• GigabitEthernet interfaces
auto-negotiation may be
incorrectly configured
• Check auto-
negotiation
configuration in the
SCE Platform and
in its and peers.
• Physical connection broken • Check / reconnect
the optical cable to
the GBE port
• Check / replace the
optical cable
• Check / replace the
cable
Comments to this Manuals