Appendix B
Chassis Group: chassisGrp (pcubeSEObjs 2)
SCE 1000 2xGBE Release 2.0.10 User Guide
OL-7117-02 B-19
chassisFansAlarm (chassisGrp 3)
Indicates whether all the fans on the chassis are functional.
Access RO
S
YNTAX
INTEGER {
1 (other): none of the following
2 (off): all fans are functional
3 (on): one or more fans is not functional.
}
chassisTempAlarm (chassisGrp 4)
Indicates the chassis temperature alarm status.
Access RO
S
YNTAX
INTEGER {
1 (other): none of the following
2 (off): temperature is within acceptable range
3 (on): temperature is too high.
}
chassisVoltageAlarm (chassisGrp 5)
Indicates the chassis internal voltage alarm status. If the alarm is ‘on’, it indicates that the voltage
level of one or more unit in the chassis is not in the normal range.
Access RO
S
YNTAX
INTEGER {
1 (other): none of the following
2 (off): voltage level is within normal range
3 (on): voltage level is out of the acceptable bounds.
}
Comments to this Manuals