Cisco SCE 1000 2xGBE User's Guide Page 355

  • Download
  • Add to my manuals
  • Print
  • Page
    / 490
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 354
Appendix A
Privileged Exec Mode Commands
SCE 1000 2xGBE Release 2.0.10 User Guide
OL-7117-02 A-85
Parameter Definition
Access Control Lists
Access Control List
number
How many ACLs will be necessary? What IP addresses will be
permitted/denied access for each management interface? You may want
ACLs for the following :
Any IP access
Telnet access
SNMP GET access
SNMP SET access
list entries (maximum 20
per list)
IP address, and whether permitted or denied access.
IP access ACL ID number of the ACL controlling IP access.
telnet ACL ID number of the ACL controlling telnet access.
SNMP Configuration
SNMP agent status Enable or disable SNMP management.
GET community names Community strings to allow GET access and associated ACLs (maximum
20).
SET community names Community strings to allow SET access and associated ACLs (maximum
20).
trap managers Trap manager IP address, community string, and SNMP version.
(maximum 20)
Authentication Failure
trap status
Set the status of the Authentication Failure trap. (See Traps (on page 6-
34).)
enterprise traps status Set the status of the enterprise traps. (See Traps (on page 6-34).)
system administrator Name of the system administrator.
Topology Configuration
connection mode Is the SCE 1000 installed in bump-in-the-wire topology (inline) or out of
line using a switch with port mirroring (receive-only)?
link bypass mode on
operational status
When the SCE 1000 is operational, should it bypass traffic or not?
Refer, in setup, to the table Setup Command Parameters.
redundant SCE 1000
platform?
Is there a redundant SCE 1000 installed as a backup?
link bypass mode on
non-operational status
When the SCE 1000 is not operational, should it bypass traffic or cut it
off?
Refer, in setup, to the table Setup Command Parameters.
operational status of the
SCE after abnormal boot
After a reboot due to a failure, should the SCE 1000 remain in a Failure
status or move to operational status provided no other problem was
detected?
Refer, in setup, to the table Setup Command Parameters.
Page view 354